Ebac Dessicant Dehumidifier Controller

Desiccant Dehumidifier Controllers for use with the DD200, DD300 & 400

Note: If you are purchasing with the dehumidifier then please select the option on the dehumidifier page. Only purchase from this page if you simply require the humidistat's.

Dehumidifier Controller 30-90% rh

!

Standard Ebac DD humidity controller

The hygrostat type HG Mini is used as an on-off controller to control the relative air humidity on the DD Desiccant range. It can also be used to control air humidifiers and dehumidifiers in offices and computer rooms. Other areas of use are storage of foodstuffs and luxury foods, cooling rooms for fruit and vegetables, greenhouses for gardening use, the textile industry, the paper and printing industry, the film industry and hospitals. The hygrostats can be used almost anywhere that air humidity has to be regulated or monitored. The room hygrostat HG Mini-i is designed so that the adjusting knob and the scale are inside the housing. This makes unauthorized manipulation by third parties more difficult.

Technical Data

scale range ............................................................ 30...90%rh

measuring accuracy ........................................................ ±3%rh

range of operation .................................................... 35...95%rh

switching difference (micro-switch) ref. to 50%rh .............approx. 4%rh


Front of DD unit is a 3 pin plug. From the unit to controller connect a .5mm or less 2-core cable. Connect to pins 1 & 2 on the DD plug (solder connection is required). The connect to the controller will be on pins 3 & 4

Price £98.00 + shipping £15.00

Humidistat Data Sheet

Remote Humidistat 1-100%

!

Wall Mounted Remote Humidistat

The Tongdy hygrostat type controls humidity between 0-100% and is ideal where a a very low rh is required. It is used as an on-off controller to control the relative air humidity on the DD Desiccant range. It can also be used to control air humidifiers and dehumidifiers in offices and computer rooms.
Other areas of use are storage of foodstuffs and luxury foods, cooling rooms for fruit and vegetables, greenhouses for gardening use, the textile industry, the paper and printing industry, the film industry and hospitals. The hygrostats can be used almost anywhere that air humidity has to be regulated or monitored.

Front of DD unit is a 3 pin plug. From the unit to controller connect a .5mm or less 2-core cable. Connect to pins 1 & 2 on the DD plug (solder connection is required). The connect to the controller will be on pins 3 & 4. The controller requires a separate 220/240 supply.

Wiring Notes:

Front of DD unit is a 3 pin plug. From the unit to controller connect a .5mm or less 2-core cable. Connect to pins 1 & 2 on the DD plug (solder connection is required). The connect to the controller will be on pins 3 & 4. Connect a 240vac supply to connector 1&2 on controller. No earth is required for the controller. The controller features 4 dip switches. Switch 1,2&4 should be in the off position. Switch 3 should be placed in the on position.

Technical Data

scale range ............................................................ 0...100%rh

measuring accuracy ........................................................ ±3%rh

range of operation .................................................... 0...100%rh

switching difference (micro-switch) ref. to 50%rh ............................................... approx. 4%rh

 

Price £159.00 + shipping £15

0-100% Controller Manual (see more details link for basic wiring set-up)